File information: | |
File name: | HP 71209A - Quick Start Guide.pdf [preview HP 71209A - Quick Start Guide] |
Size: | 335 kB |
Extension: | |
Mfg: | Agilent |
Model: | HP 71209A - Quick Start Guide 🔎 |
Original: | HP 71209A - Quick Start Guide 🔎 |
Descr: | Agilent HP 71209A Series System Folder HP 71209A - Quick Start Guide.pdf |
Group: | Electronics > Other |
Uploaded: | 28-08-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name HP 71209A - Quick Start Guide.pdf Quick Start Guide HP 71209A Microwave Spectrum Analyzer ABCDE HP Part No. 71209-90001 Printed in USA October 1991 Edition B.0.0 Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and tness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Restricted Rights Legend. Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c) (1) and (c) (2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for other agencies. Copyright Hewlett-Packard Company 1991 c All Rights Reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. 1400 Fountaingrove Parkway, Santa Rosa, CA 95403-1799, USA WARNING Before applying power to this instrument, make sure it has been properly grounded through the protective conductor of the ac power cable to a socket outlet provided with protective earth contact. Any interruption of the protective (grounding) conductor, inside or outside the instrument, or disconnection of the protective earth terminal can result in personal injury. CAUTION Before applying power to this instrument, make sure its primary power circuitry has been adapted to the voltage of the ac power source. Failure to set the ac power input to the correct voltage could cause damage to the instrument when the ac power cable is plugged in. CAUTION Total input power to the front-panel RF INPUT connector must not exceed +30 dBm. Power in excess of +30 dBm may damage the instrument. CAUTION Electrostatic discharge (ESD) can damage circuits associated with rear-panel connectors. Therefore, before connecting any cable to a rear-panel connector, momentarily short the center and outer conductors of the cable together. Avoid touching the rear-panel connectors without rst touching the frame of the instrument. Be sure that the spectrum analyzer is properly earth-grounded to prevent buildup of static charge. iii The HP 71209A - At A Glance The HP 71209A modular spectrum analyzer has a full-band sweep from 100 Hz to 26.5 GHz and built-in external millimeter mixer capability. The standard system consists |
Date | User | Rating | Comment |